| Sign In | Join Free | My burrillandco.com | 
 | 
| Ask Lasest Price | |
| Brand Name : | Supmeter | 
| Model Number : | BST106-F11 | 
| Certification : | CE | 
| Payment Terms : | T/T, Western Union | 
| Supply Ability : | 500pcs per month | 
| Delivery Time : | 3-30 working days | 
| Price : | negotiation | 
Weighing & Totalizing Controller With Weight Display, Setpoint DO Output, Manual/Auto Totalizing
Main Features:
Picture





If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically.
| Menu Operation | |
| Key Name | Description | 
| 【MENU】 | Enter Main Menu / Exit. | 
| 【ENT】 | Enter / Save / Alarm Acknowledge. | 
| 【◄】 | Cursor shifts left. | 
| 【►】 | Cursor shifts right. | 
| 【▲】 | Display the previous interface or option. Digit input: +1. | 
| 【▼】 | Display the next interface or option. Digit input: -1. | 
| Quick Operation | |
| 【Ñ】 * | 
 | 
| 【SET】 | Setpoint parameters setting. | 
| 【G/N】 | Gross Weight / Net Weight display switch. | 
| 【F1】 | Cancel Totalizing. | 
| 【→C←】 【CAL】 * | Load Calibration. | 
| 【→0←】 【ZERO】 * | 
 | 
| 【→T←】 【TARE】 * | 
 | 
| 【,】* | Unused. | 
| 【/】* | Clear Screen: Clear the display value of Net Weight of Present Batch, Totalized Net Weight and Batch Count. | 
| 【‡】* | Time display and setting. | 
| 【±】 | ‘+’/‘-’ switch. | 
| 【6】 | 
 | 
| 【∑】 | Manual Totalizing: Net Weight Totalizing and Batch Counting. | 
*: Keep the key pressed for 2 seconds.
| Sign | Description | 
| [GROSS] | Gross Weight display. | 
| [NET] | Net Weight display. | 
| [SUM] | ON: The Net Weight of present batch has been totalized into ‘Totalized Net Weight’ and DO5 switch turns on. | 
| [LOCK] | ON: Key-locked. OFF: Key-unlocked. | 
| [◣◢] | Weight is stable: Weight Variance per [107] ‘Stablity Judging Time’ is in [106] ‘Stablity Judging Range’. | 
| [→0←] | The present Gross Weight or Net Weight display value is in ‘Display Value Auto-Zero Range’. | 
| [kg/t/g] | Weight unit. | 
| [ PCS] | Batch Count display. | 
| [TOT] | Totalized Net Weight display. | 
| [SET] | Parameter setting state. | 
| [RUN] | ON: Weighing state. OFF: Calibrating state. | 
| [ZERO] | Net Weight ≤ Non-load Zero Range. | 
| [NZ] | It’s allowed to do Zero Fine Adjustment. | 
| [FILL] | Weight value is increasing. | 
| [COMP] | Auto Totalizing function is open. | 
| [DISC] | Weight value is reducing. | 
| [HH] | Weight Uppermost Limit / Weight Setpoint 4. | 
| [HI] | Weight Upper Limit / Weight Setpoint 3. | 
| [LO] | Weight Lower Limit / Weight Setpoint 2. | 
| [LL] | Weight Lowest Limit / Weight Setpoint 1. | 


|   | 
 
                                 
                                 
                                 
                                