    • Product Details
    • Company Profile

    Automatic Bagging Packing Controller For Weighing Hopper Scale

    Automatic Bagging Packing Controller For Weighing Hopper Scale


    Main Features:

    • EMC design with high anti-jam for industrial environment.
    • DC24V power input with reverse polarity protection
    • Cortex-A8 CPU with 600MHz Clock, 128M RAM and 128M Flash.
    • 7”[800x480] or10.2” [1024x600] TFT touch panel
    • 24-bit ∑-△ADC with internal resolution 1/1,000,000

    • High sampling frequency 800Hzer Packing] and Respective[Single-hopper Packing].
    • Special Anti-vibration Digital Filtering Algorithm for precise weighing, stable display and rapid response.
    • Auto Zero Tracking
    • Fall Value Auto Correction.
    • Auto Pause for Deviation Alarm.
    • Auto Re-feed for Negative Deviation Alarm.
    • Target Batch Count & Target Batch Weight Control.
    • Definable DI/DO/AO/COM[Communication Port].
    • 3-speed[high/medium/low] feeding control by DOs or AOs.
    • Recipe Number: 100.

    Technical Specification:

    • Power Supply: DC24V±20%, Max. 10W.
    • Loadcell Excitation Voltage/Current: DC5V/250mA.
    • 16 Loadcells[350Ω] connectable.
    • Weighing Signal Input Range: 0~12.5mV.
    • 9 Normally Open Switch Inputs [DI].
    • 18 Normally Open Transistor Outputs [DO]: DC24V, 500mA.
    • 2 Analog Signal Outputs [AO]: 0~10V, Max.50mA.
    • COM&COM1: RS232; COM2: RS485.
    • USB1: Connect mouse, software download, data backup.
    • LAN: Optional Ethernet.
    • Outline Size [W×H×D]
    • 7”: 226.5 × 163 × 36 mm.
    • 10.2”: 274 × 193 × 40 mm.
    • Panel Cut-out Size [W×H]
    • 7”: 215 × 152 mm.
    • 10.2”: 261 × 180 mm.
    • Operating Temperature: -25℃~+45℃.
    • Protection Level of Front Panel: IP65.
    • Accuracy Grade: III.
    • Verification Accuracy: 0.02%.
    • Static Weighing Accuracy: 0.2%~0.5%.
    • Packing Accuracy: 0.2%~0.5%

    Software Function

    • Manual Screen-locking/Screen-unlocking, Auto Screen-locking, Digital Setting&Calibration and I/O Testing functions available.
    • Initial Zero Adjustment after Power-on, Auto Zero Tracking, Zero Fine Adjustment and Zero Calibration functions available.
    • Load Calibration and Loss Calibration functions available.
    • 10 Recipes for packing control.
    • Optional ‘Fall Value Auto Correction’ function.
    • Optional ‘Auto Pause for Deviation Alarm’ and ‘Auto Re-feed’ functions.
    • Optional ‘Target Batch Control’ function [With Target Batch Count or Target Batch Weight finished, the packing process will stop automatically].
    • The Batch Records can be printed automatically.
    • Historical Batch Records, Totalizing Reports and Recipes can be queried and printed.
    • With the multitasking mode, the weighing&control process will not be interrupted by parameter setting and the other operations.

    Button Operation

    NameOperationState IndicatorAuthorization
    【Auto】Auto / Manual [Emergency Stop] switch.

    Green: Auto state.

    Grey: Manual state.

    All Users
    【Start】Start.

    Green: Running state.

    Grey: Stop state.

    【Re-run】Clear Alarm & Recover Running.
    【Last】

    Last Batch [Normal Stop].

    Stop after the present batch finished.

    Flashing Red.
    【E-stop】Emergency Stop.
    【Alarm】

    Alarm Query / Clear Alarm.

    ‘Auto/Pause’ state: Recover Running after clearing alarm.

    Red: Alarm state.
    【Print】

    Report Print:

    • [ Auto Print]: Print Batch Records.
    • [Total]: Print Totalizing Report.
    • [Recipe]: Print Working Recipe.
    【Lock】

    Screen-locking: Locking/unlocking the operating buttons of main display interface.

    Auto Screen-locking: Refer to parameter [901].

    Flashing Red: Locked.

    Grey: Unlocked.

    【Menu】Enter Main Menu.
    【User】User Login. Display: Operator / Engineer / Admin.
    【Zero】Zero Fine Adjustment [No Power-down Protection].Flashing green.
    【Bag】Bag-clamp/release Request.

    Green: Bag-clamping state.

    Grey: Bag-releasing state.

    【High】Manual Start/Stop High-speed Feeding.Green: Working state.
    【Med】Manual Start/Stop Medium-Speed Feeding.
    【Low】Manual Start/Stop Low-speed Feeding.
    【Dump】Manual Start/Stop Dumping.
    【Clear】Clear Screen: Clear the display values of Feeding Weight, Totalized Weight, Batch Count and Packing Speed.

    Engineer

    Administrator


    Data Display & Quick Setting

    NameDescriptionAuthorization
    Biggest DigitsReal-time Weight [Weight Unit].
    [HI]Weight Upper Limit Alarm.
    [OL]Overload Alarm.
    [CYCLES]Batch Count.
    [FINAL]Final Feeding Weight.
    [▲]/[HI]Positive Deviation Alarm.
    [▼]/[LO]Negative Deviation Alarm.
    [RUN]Auto Running state.
    [PAUSE]Pause state.
    [P_SW]DI switch ‘Dumping Gate Closed in Place’ turned on.
    [ZERO]Weight ≤ Non-load Zero Range.
    [STAB]Weight is stable.
    [FED]Feeding Ended.
    [FIN]Target Batch [Count/Weight] Finished.
    [SPLY]In the process of ‘Supplying Material into Feeding Hopper’.

    [LABEL]/[GAS]/

    [SEW]/[CUT]

    In the process of ‘Labeling on Bag’ / ‘Filling Gas into Bag’ / Bag-sewing / Thread-cutting.
    [RECIPE]‘Working Recipe’ Setting.All Users
    [TARGET]‘Target Value’ Setting.
    [SP1]SP1 Lead Value for High-speed Feeding.
    [SP2]SP2 Lead Value for Medium-speed Feeding.
    [FALL]SP3 Fall Value for Low-speed Feeding.
    • ‘AUTO FALL’: Fall Value Auto Correction function is open.
    • ‘FREE FALL’: Fall Value Auto Correction function is closed.
    [Mode]

    APP1.1 1-Hopper Mode / APP1.2 2-Hopper&1-Bag Mode / APP1.3 2-Hopper&2-Bag Mode / APP2.1 1-Bag Mode / APP2.2 2-Bag Mode.

    Refer to Parameter [300] ‘Application Mode’.

    [Au-supply DI]‘Material Auto-supply Permit ’ DI truns ON/OFF.
    [Date&Time]Date&Time.
    [BAT. CNT]Target Batch Count.
    [SUM CYCLES]Batch Count.
    [BAT. WT]Target Batch Weight.
    [TOTAL]Totalized Weight.
    [CPM]Packing Speed [Cycles/min].

    Outline Size


    Installation Mode

    Terminal Diagram

    Hopper-weighing with one Bag-clamping Mode:


    Double-hopper-weighing with one Bag-clamping Mode:


    System Diagram for APP3 Loss-in-weight Mode


    Double-hopper-weighing with two Bag-clampings Mode:

    Quality Automatic Bagging Packing Controller For Weighing Hopper Scale for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: CHANGSHA SUPMETER TECHNOLOGICAL CO.,LID
    *Subject:
    *Message:
    Characters Remaining: (0/3000)